logo

The CleanAir Quality System

 

We have similiar benefit lists for: Stack Testing - Instrument Rental - Express Equipment Sales - Consulting Services - Analytical Services - Engine Services - Flow CEM - Instrument RepairSCR Tuning

Use the table slide bar to see  more benefits


Back to Benefit Table Index

Benefits of our Instrument Rental Quality System

Use the table slide bar to see  more benefits

Help us improve this page


Benefit - Problem - Need - Value CleanAir's System What To Look For Bias Error Possible Outcome
Equipment that works correctly out of the box Continuous improvement. PDSA * * *
Elimination of instrument damage due to shipping Instruments & packaging engineered to withstand rough handling and vibration.  Custom designed packing and shipping containers. Works out of the box 99.9% of time. Shipping damage generally make the instrument DOA. Delayed or rescheduled testing program.
More accurate measurement of turbulent flow. Cyclonic flow can be determination on every stack and use our auto 3D flow probe. Situations where a more accurate flow measurement is required by EPA Methods or will result in big benefits . Up to + 25% total gas flow error. Error generally penalizes source operator. Increased reported total pounds per hour emissions by up to 15%. Buy more or sell fewer emission credits, reduce production.
Benefit - Problem - Need - Value CleanAir's System What To Look For Bias Error Possible Outcome
Analytical instruments shipped from job to job without checkup or cleaning. Bench check instruments after each job with the instrument technicians card attached to the top. Ask to see the instrument log repair history file and bench calibration.    
Heated sample lines shipped from job to job without checkup or cleaning Flush HSL after each job then using CO and THC analyzers to confirm that the residual levels are non detect. HSL shipping box label. HSL maintenance history file and cleaning test chart.    
Variation caused by field contamination. Pretest field blank for every test, even if not required by the test method. Extra sample train a the test location with full setup and recovery.    
Benefit - Problem - Need - Value CleanAir's System What To Look For Bias Error Possible Outcome
Port air in-leakage contamination.   Gloves in ports and low gas temperatures at points nearest ports    
Contaminated blanks. Instrument grade reagents and new glassware for every reagent preparation. Lab blanks that are more than the sample.    
Negative sample weights. We pre-condition filters before use and select the filter media will not be attacked by the compounds present in the sample gas. Negative sample weights.    
Field delays and problems caused by test equipment failure. Rugged and dependable test equipment. Is it engineered to eliminate failure?  Is it well maintained? Equipment failure contingency plan. Possible bias error but bigger concern should be fabrication to replace lost data. Delayed testing. Prolonged process operation at test condition, such as reduced load,could be very costly. 
Lost of computer stored test data. Back-up all project-related computer files on a DAILY basis in field and office. Field computer backup disk which is stored off site. Ask to see office backup system. No bias error unless data is fabricated to replace lost data. Repeat of testing program may be needed but may not be possible in special situations.
Making Corrections to Hand-Recorded Data        
Documentation storage and retrival system        
Benefit - Problem - Need - Value CleanAir's System What To Look For Bias Error Possible Outcome
Safety first Safe work habits. Safety is Cleanair's highest priority!  Our aim is zero accidents. NA An accidents can cause major problems. We work to eliminate this possibility.
Dry gas meter calibration drift to unacceptable value. Field monitoring of dry gas meter’s performance on an on-going basis.      
More accurate measurement of turbulent flow. Cyclonic flow can be determination on every stack and use our auto 3D flow probe. Situations where a more accurate flow measurement is required by EPA Methods or will result in big benefits . Up to + 25% total gas flow error. Error generally penalizes source operator. Increased reported total pounds per hour emissions by up to 15%. Buy more or sell fewer emission credits, reduce production.
Benefit - Problem - Need - Value CleanAir's System What To Look For Bias Error Possible Outcome
         
         
         
         
Benefit - Problem - Need - Value CleanAir's System What To Look For Bias Error Possible Outcome