NSPS Particulate Testing Requirements (40 CFR 60)

All subparts specify EPA Method 5 unless otherwise specified.

N/S = Not Specified.  In these cases, either process-specific or Method 1-5 requirements would apply.

 

 

 

 

Subpart

 

 

 

 

Facility

 

Minimum Sample Time (minutes)

 

Minimum Sample Volume (dscf)

 

 

Filter Temperature (°F)

 

 

 

 

Comments

D

Fossil-fired boilers

60

30

320±25°F

Method 5B required after FGD

Da

Electric Utilities

120

60

320±25°F

Method 5B required after FGD

Db

Industrial Boilers

120

60

320

Method 5B required after FGD  Method 17 allowed if gas temperature is less than 320°F.

Dc

Small Industrial Boilers

120

60

320

Method 5B required after FGD  Method 17 allowed if gas temperature is less than 320°F.

Ea

Municipal Waste Combustors, 1989-1994 construction

N/S

60

320±25°F

 

Eb

Municipal Waste Combustors, constructed after 1994

N/S

60

320±25°F

240 minute test specified for Dioxins

Ec

Hospital Incinerators

60

N/S

N/S

240 minute test specified for Dioxins

F

Portland Cement Mfg.

60

30

N/S

40.6 dscf required for Clinker Cooler

N

Basic Oxygen Process, Primary Emissions

60

53

N/S

Integral # of heats or blows.

NA

Basic Oxygen Process, Secondary Emissions

N/S

200

N/S

Sampling done only during steel production.

O

Sewage Treatment Facilities

60

31.8

N/S

 

P

Primary Copper Smelters

60

30

N/S

 

Q

Primary Zinc Smelters

60

30

N/S

 

R

Primary Lead Smelters

60

30

N/S

 

Y

Coal Preparation Plants

60

30

N/S

Sampling must begin no less than 30 minutes after startup and end before shutdown procedures commence.

Z

Ferro-Alloy Electric Arc Furnaces (EAF)

60

63.6

N/S

Integral # of furnace cycles.

AA

Steel EAF, 1974-1983 construction

240

160

N/S

Integral # of heats if single furnace. Use Method 5D for Positive Pressure Baghouses.

AAa

Steel EAF/AOD, constructed after 1983

240

160

N/S

Integral # of heats if single furnace. Use Method 5D for Positive Pressure Baghouses.

BB

Kraft Pulp Mills

60

31.8

N/S

Use water instead of acetone to rinse

CC

Glass Mfg.

60

31.8

350±25°F

248±25°F if gas-fired or <0.5%w/w sulfur oil

DD

Grain Elevators

60

60

Ambient

No heaters allowed

HH

Lime Mfg.

60

31.8

N/S

5D for positive pressure baghouses

LL

Metallic Mineral Processing

N/S

60

<250

Method 17 allowed.

NN

Phosphate Rock Processing

60

30

N/S

 

PP

Ammonium Sulfate Mfg.

60

53

N/S

 

UU

Asphalt and Asphalt Roofing Materials Mfg.

120

106

N/S

Method 5A specifies 108±18°F

OOO

Non-metallic Mineral Processing

N/S

60

<250

Allows Method 17

PPP

Wool Fiberglass Insulation Mfg.

120

90

N/S

Method 5E required

UUU

Calciners and Dryers in Mineral Processing

120

60

N/S